Table 10: FCC 6 viol 1.4

One Meter Table A1 Table A2 Table A3 Table A4
Duty Cycle 60% 100% 1000% 2000%
Reflection Reflection Reflection Reflection
1% 2.1 uW/cm2 3.3 99 361
10% 21 33 989* 3606*
20% 42 65 1979* 7212*
30% 63 98 2968* 10818*
40% 83 131 3958* 14424*
50% 105 164 4947* 18030*
60% 105 196 5936* 21636*
70% 147 229 6926* 25241*
80% 168 262 7915* 28847*
90% 188 294 8904* 32453*
100% 209 327 9894* 36059*
Four Meters Table A5 Table A6 Table A7 Table A8
Duty Cycle 60% 100% 1000% 2000%
Reflection Reflection Reflection Reflection
15 uW/cm2 24 712* 2596*
10% 151 236 7124* 25963*
20% 301 471 14247* 51925*
30% 452 707* 21371* 77888*
40% 603 942* 28494* 103850*
50% 754* 1177* 35618* 129813*
60% 904* 1413* 42741* 155775*
70% 1055* 1648* 49865* 181738*
80% 1206* 1884* 56988* 207701*
90% 1356* 2119* 64112* 233663*
100% 1507* 2355* 71235* 259626*

This table shows RF power density for face reading a meter at 6″ distance.

*Exceeds 655 uW/cm2 at 6″ at the face.