Table 3: Nursery Data
One Meter | Table A17 | Table A18 | Table A19 | Table A20 |
---|---|---|---|---|
Duty Cycle | 60% | 100% | 1000% | 2000% |
Reflection* | Reflection | Reflection* | Reflection* | |
1% | 1.4 | 2.2 | 66 | 241 |
5% | 7 | 11 | 331 | 1227 |
10% | 14 | 21.9 | 662 | 2414 |
20% | 28 | 43.8 | 1324 | 4828 |
30% | 42 | 65.7 | 1986 | 7242 |
40% | 56.1 | 87.6 | 2649 | 9655 |
50% | 70.1 | 109 | 3312 | 12069 |
60% | 84.1 | 131 | 3974 | 14483 |
70% | 98.1 | 153 | 4636 | 16897 |
80% | 112 | 175 | 5299 | 19311 |
90% | 126 | 197 | 5961 | 21175 |
100%*** | 140 | 218 | 6623 | 24139 |
Four Meters* | Table A21 | Table A22 | Table A23 | Table A24 |
---|---|---|---|---|
Duty Cycle | 60% | 100% | 1000% | 2000% |
Reflection* | Reflection | Reflection* | Reflection* | |
1% | 4.9 | 7.5 | 227 | 828 |
5% | 24 | 38 | 1137 | 4142 |
10% | 48 | 75 | 2273 | 8284 |
20% | 96 | 150 | 4546 | 16569 |
30% | 144 | 225 | 6819 | 24853 |
40% | 192 | 301 | 9092 | 33137 |
50% | 240 | 376 | 11365 | 41421 |
60% | 289 | 451 | 13638 | 49705 |
70% | 337 | 526 | 15911 | 57990 |
80% | 385 | 601 | 18184 | 66274 |
90% | 433 | 676 | 20457 | 74558 |
100%*** | 481 | 751 | 22730 | 82843 |
This table shows RF power density for readings at 11 in the crib.
*Note: 1000-2000% reflection based on Vermeeren et al, 2010; Christ et al, 2010; Hondou, 2002.
**More than 4 meters placed together do not appreciably increase the exposure to one reference point such as a crib or bed. However, multiple meters can increase the square footage of space similarly affected.
***Continuous exposure is required in calculations of time-weighted average radiofrequency exposure for uncontrolled public access by FCC OET 65 (p. 15).