Table 13: Nursery FCC 576 629
One Collector | Table A25 | TableA26 | Table A27 | Table A28 |
---|---|---|---|---|
Duty Cycle | 60% | 100% | 1000% | 2000% |
571 limit | Reflection | Reflection | Reflection | Reflection |
1% | 4.0 uW/cm2 | 6.2 | 187 | 680* |
5% | 19.7 | 30.8 | 933* | 3399* |
10% | 39.5 | 61.7 | 1865* | 6798* |
20% | 78.9 | 123 | 3730* | 13596* |
30% | 118 | 185 | 5596* | 20394* |
40% | 158 | 247 | 7461* | 27192* |
50% | 197 | 308 | 9326* | 33990* |
60% | 237 | 370 | 11191* | 40788* |
70% | 276 | 432 | 13056* | 47586* |
80% | 316 | 493 | 14922* | 54384* |
90% | 355 | 555 | 16787* | 61182* |
100% | 395 | 617* | 18652* | 67980* |
One Collector +3 Meters* | Table A29 | Table A30 | Table A31 | Table A32 |
---|---|---|---|---|
Duty Cycle | 60% | 100% | 1000% | 2000% |
624 limit | Reflection | Reflection | Reflection | Reflection |
1% | 7.4 uW/cm2 | 11.5 | 348 | 1267* |
5% | 36.8 | 57.5 | 1738* | 6334* |
10% | 73.5 | 115 | 3476* | 12668* |
20% | 147 | 230 | 6952* | 25337* |
30% | 221 | 345 | 10428* | 38005* |
40% | 294 | 460 | 13904* | 50674* |
50% | 368 | 575 | 17380* | 63342* |
60% | 441 | 689* | 20855* | 76010* |
70% | 515 | 804* | 24331* | 88679* |
80% | 588 | 919* | 27807* | 101347* |
90% | 662 | 1034* | 31283* | 114015* |
100% | 735 | 1149* | 34759* | 126684* |
This table shows RF power density FCC violations at 11″