Table 15: Kitchen FCC 576 629

One Collector Table A41 Table A42 Table A43 Table A44
Duty Cycle 60% 100% 1000% 2000%
571 limit Reflection Reflection Reflection Reflection
1% 0.6 uW/cm2 1 28.8 105
5% 3.1 4.8 144 525
10% 6.1 9.5 288 1049*
20% 12.2 19 576* 2098*
30% 18.3 28.6 864* 3148*
40% 24.4 38.1 1152* 4197*
50% 30.5 47.6 1439* 5246*
60% 36.5 57.1 1727* 6295*
70% 42.6 66.6 2015* 7344*
80% 48.7 75.1 2303* 8393*
90% 54.8 85.7 2591* 9243*
100% 60.9 95.2 2879* 10492*
One Collector +3 Meters** Table A45 Table A46 Table A47 Table A48
Duty Cycle 60% 100% 1000% 2000%
624 limit Reflection Reflection Reflection Reflection
1% 0.9 uW/cm2 1.5 45 162
5% 4.7 7.4 223 811*
10% 9.4 14.7 445 1622*
20% 18.8 29.4 890* 3245*
30% 28.3 44.2 1336* 4867*
40% 37.7 58.9 1781* 6490*
50% 47.1 73.6 2226* 8112*
60% 56.5 88.3 2671* 9734*
70% 65.9 103 3116* 11357*
80% 75.4 118 3561* 12979*
90% 84.8 132 4006* 14602*
100% 94.2 147 4452* 16224*

This table shows RF power density readings at 28″ in the kitchen work space.

*Exceeds 571/624 uW/cm2 FCC Limit