One Meter |
Table A33 |
Table A34 |
Table A35 |
Table A36 |
Duty Cycle |
60% |
100% |
1000% |
2000% |
|
Reflection |
Reflection |
Reflection |
Reflection |
1% |
0.2 |
0.3 |
10.2 |
37.3 |
5% |
1.1 |
1.7 |
51.1 |
186 |
10% |
2.2 |
3.4 |
102* |
373* |
20% |
4.3 |
6.8 |
204* |
745* |
30% |
6.5 |
10.1 |
307* |
1118* |
40% |
8.7 |
13.5 |
409* |
1490* |
50% |
10.8 |
16.9 |
511* |
1863* |
60% |
13 |
20.3 |
613* |
2235* |
70% |
15.1 |
23.7 |
716* |
2608* |
80% |
17.3 |
27 |
818* |
2980* |
90% |
19.5 |
30.4 |
920* |
3353* |
100% |
21.6 |
33.8 |
1022* |
3726* |
Four Meters |
Table A37 |
Table A38 |
Table A39 |
Table A40 |
Duty Cycle |
60% |
100% |
1000% |
2000% |
|
Reflection |
Reflection |
Reflection |
Reflection |
1% |
0.6 |
0.9 |
26 |
94.6* |
5% |
2.8 |
4.3 |
129* |
473* |
10% |
5.5 |
8.6 |
260* |
946* |
20% |
11 |
17.2 |
519* |
1892* |
30% |
16.5 |
25.7 |
779* |
2837* |
40% |
22 |
34.3 |
1038* |
3783* |
50% |
27.5 |
42.9 |
1298* |
4729* |
60% |
32.9 |
51.5 |
1557* |
5675* |
70% |
38.4 |
60.1 |
1817* |
6621* |
80% |
43.9 |
68.6 |
2076* |
7566* |
90% |
49.4 |
77.2 |
2336* |
8512* |
100% |
54.9 |
85.8 |
2595* |
9458* |
*Exceeds 92.5 uW/cm2