Table 4: Nursery Data

One Collector Table A25 Table A26 Table A27 Table A28
Duty Cycle 60% 100% 1000% 2000%
Reflection Reflection Reflection* Reflection*
1% 4.0 uW/cm2 6.2 187 680
5% 19.7 30.8 933 3399
10% 39.5 61.7 1865 6798
20% 78.9 123 3730 13596
30% 118 185 5596 20394
40% 158 247 7461 27192
50% 197 308 9326 33990
60% 237 370 11191 40788
70% 276 432 13056 47586
80% 316 493 14922 54384
90% 355 555 16787 61182
100%*** 395 617 18652 67980
One Collector + 3 Meters* Table A29 Table A30 Table A31 Table A32
60% 100% 1000% 2000%
Duty Cycle Reflection Reflection Reflection* Reflection*
1% 7.4 uW/cm2 11.5 348 1267
5% 36.8 57.5 1738 6334
10% 73.5 115 3476 12668
20% 147 230 6952 25337
30% 221 345 10428 38005
40% 294 460 13904 50674
50% 368 575 17380 63342
60% 441 689 20855 76010
70% 515 804 24331 88679
80% 588 919 27807 101347
90% 662 1034 31283 114015
100%*** 735 1149 34759 126684

This table shows RF power density for readings at 11 in the crib.

*Note: 1000-2000% reflection based on Vermeeren et al, 2010; Christ et al, 2010; Hondou, 2002.

**More than 4 meters placed together do not appreciably increase the exposure to one reference point such as a crib or bed. However, multiple meters can increase the square footage of space similarly affected.

***Continuous exposure is required in calculations of time-weighted average radiofrequency exposure for uncontrolled public access by FCC OET 65 (p. 15).