Table 6: Kitchen Data

One Collector Table A41 Table A42 Table A43 Table A44
Duty Cycle 60% 100% 1000% 2000%
Reflection Reflection Reflection* Reflection*
1% 0.6 uW/cm2 1 28.8 105
5% 3.1 4.8 144 525
10% 6.1 9.5 288 1049
20% 12.2 19 576 2098
30% 18.3 28.6 864 3148
40% 24.4 38.1 1152 4197
50% 30.5 47.6 1439 5246
60% 36.5 57.1 1727 6295
70% 42.6 66.6 2015 7344
80% 48.7 75.1 2303 8393
90% 54.8 85.7 2591 9243
100%*** 60.9 95.2 2879 10492
One Collector +3 Meters** Table A45 Table A46 Table A47 Table A48
60% 100% 1000% 2000%
Duty Cycle Reflection Reflection Reflection* Reflection*
1% 0.9 uW/cm2 1.5 45 162
5% 4.7 7.4 223 811
10% 9.4 14.7 445 1622
20% 18.8 29.4 890 3245
30% 28.3 44.2 1336 4867
40% 37.7 58.9 1781 6490
50% 47.1 73.6 2226 8112
60% 56.5 88.3 2671 9734
70% 65.9 103 3116 11357
80% 75.4 118 3561 12979
90% 84.8 132 4006 14602
100%*** 94.2 147 4452 16224

This table shows RF power density for readings at 28 in the kitchen work space.

*Note: 1000-2000% reflection based on Vermeeren et al, 2010; Christ et al, 2010; Hondou, 2002.

**More than 4 meters placed together do not appreciably increase the exposure to one reference point such as a crib or bed. However, multiple meters can increase the square footage of space similarly affected.

***Continuous exposure is required in calculations of time-weighted average radiofrequency exposure
for uncontrolled public access by FCC OET 65 (p. 15).